LSNP Usage Rules

RULE ID:LSNP_ADMIN_LQTY_1
DESCRIPTION:The valid length for LQTY is 1-5 numeric characters.

RULE ID:LSNP_ADMIN_LQTY_2
DESCRIPTION:LQTY must equal to the number of occurrences of the LNA field.

RULE ID:LSNP_ADMIN_LQTY_3
DESCRIPTION:LQTY is required.

RULE ID:LSNP_ADMIN_1
DESCRIPTION:LSNP Admin section is required.

RULE ID:LSNP_ADMIN_NPQTY_1
DESCRIPTION:The valid length for NPQTY is 1-5 numeric characters.

RULE ID:LSNP_ADMIN_NPQTY_2
DESCRIPTION:NPQTY is required.

RULE ID:LSNP_SVC_DET_NPI_1
DESCRIPTION:The valid value for NPI is B when ACT is V.

RULE ID:LSNP_SVC_DET_RL_1
DESCRIPTION:RL is prohibited when LNA does not equal V.

RULE ID:LSNP_SVC_DET_RL_2
DESCRIPTION:Valid value for RL is Y.

RULE ID:LSNP_SVC_DET_TNT_1
DESCRIPTION:Valid values for TNT are A, B or C.

RULE ID:LSNP_SVC_DET_TNT_2
DESCRIPTION:TNT = A is prohibited when SPEC = LOOPEEL or NC = HCE- and NCI = 04QDU9.ISN, 04QB9.11 or NC = HC-- and NCI = 04QB9.11, 04QDU0.ISN or NC = HF-- and NCI = 04QB6.33.

RULE ID:LSNP_SVC_DET_OECCKT_1
DESCRIPTION:Valid length for OECCKT must be between 15-36 characters.

RULE ID:LSNP_SVC_DET_OECCKT_2
DESCRIPTION:OECCKT is required when RL is populated.

RULE ID:LSNP_SVC_DET_OECCKT_3
DESCRIPTION:OECCKT is prohibited if LNA does not equal V and RL is not populated.

RULE ID:LSNP_SVC_DET_CFA_1
DESCRIPTION:Valid length for CFA is 1-42 alpha numeric characters.

RULE ID:LSNP_SVC_DET_CFA_2
DESCRIPTION:Either CFA or CCEA must be populated.

RULE ID:LSNP_SVC_DET_PORTED_NBR_1
DESCRIPTION:PORTEDNBR is required.

RULE ID:LSNP_SVC_DET_PORTED_NBR_2
DESCRIPTION:Valid format for PORTEDNBR is NNN-NNN-NNNN.

RULE ID:LSNP_SVC_DET_NPT_1
DESCRIPTION:NPT is required when LNA = N, T, V.

RULE ID:LSNP_SVC_DET_NPT_2
DESCRIPTION:Valid value for NPT is D.

RULE ID:LSNP_SVC_DET_RTI_1
DESCRIPTION:Valid length for RTI is 1-6 alphanumeric characters.

RULE ID:LSNP_SVC_DET_NPTG_1
DESCRIPTION:Valid format for NPTG is AANNNNNN (where A = alpha and N = numeric).

RULE ID:LSNP_SVC_DET_TSP_1
DESCRIPTION:Valid format for TSP is XXXXXXXXX-XN (where X = alphanumeric and N = numeric).

RULE ID:LSNP_SVC_DET_TSP_2
DESCRIPTION:Valid values for the 11th position of TSP are E, 0, 1, 2, 3, 4, 5.

RULE ID:LSNP_SVC_DET_TSP_3
DESCRIPTION:Valid values for the 12th position of TSP are 0, 1, 2, 3, 4, 5.

RULE ID:LSNP_SVC_DET_SAN_1
DESCRIPTION:Valid length for SAN is 1-30 alphanumeric characters.

RULE ID:LSNP_SVC_DET_CCEA_1
DESCRIPTION:Valid length for CCEA is 1-60 alphanumeric characters.

RULE ID:LSNP_SVC_DET_SYSTEM_ID_1
DESCRIPTION:Valid length for SYSTEMID is 1-5 alphanumeric characters.

RULE ID:LSNP_SVC_DET_RELAY_RACK_1
DESCRIPTION:RELAYRACK Valid Length = 1-10 alphanumeric characters.

RULE ID:LSNP_SVC_DET_SHELF_1
DESCRIPTION:SHELF valid length = 1-6 alphanumeric characters.

RULE ID:LSNP_SVC_DET_SHELF_2
DESCRIPTION:SHELF is prohibited if RELAYRACK not populated.

RULE ID:LSNP_SVC_DET_SLOT_1
DESCRIPTION:SLOT valid length = 1-4 alphanumeric characters.

RULE ID:LSNP_SVC_DET_SLOT_2
DESCRIPTION:SLOT is prohibited if SHELF not populated.

RULE ID:LSNP_SVC_DET_LEAN_1
DESCRIPTION:LEAN valid length = 1-20 alphanumeric characters.

RULE ID:LSNP_SVC_DET_LEAN_2
DESCRIPTION:LEAN is prohibited when ACT does not equal "V" or LEATN is populated.

RULE ID:LSNP_SVC_DET_LEATN_1
DESCRIPTION:Valid format for LEATN is NNN-NNN-NNNN.

RULE ID:LSNP_SVC_DET_LEATN_2
DESCRIPTION:LEATN is prohibited when ACT does not equal "V" or LEAN is populated.

RULE ID:LSNP_SVC_DET_CTI_1
DESCRIPTION:CTI valid values are A, B or C.

RULE ID:LSNP_SVC_DET_CTI_2
DESCRIPTION:CTI is prohibited when 2nd position TOS does not equal P, R or CABLEID is not populated.

RULE ID:LSNP_SVC_DET_CABLE_ID_1
DESCRIPTION:CABLEID valid length = 1-5 alphanumeric characters.

RULE ID:LSNP_SVC_DET_CBCID_1
DESCRIPTION:CBCID valid length = 1-10 alphanumeric characters.

RULE ID:LSNP_SVC_DET_CBCID_2
DESCRIPTION:CBCID is prohibited except when SLI = B.

RULE ID:LSNP_SVC_DET_CHAN_PAIR_1
DESCRIPTION:CHANPAIR valid length = 1-5 alphanumeric characters.

RULE ID:LSNP_SVC_DET_LOCNUM_1
DESCRIPTION:LOCNUM is required field in LSNP form.

RULE ID:LSNP_SVC_DET_LOCNUM_2
DESCRIPTION:Valid values for LOCNUM are 1, 01, 001.

RULE ID:LSNP_SVC_DET_LNUM_1
DESCRIPTION:LNUM valid length is 1-5 numeric.

RULE ID:LSNP_SVC_DET_LNUM_2
DESCRIPTION:LNUM is required field.

RULE ID:LSNP_SVC_DET_LNA_1
DESCRIPTION:LNA is required.

RULE ID:LSNP_SVC_DET_LNA_2
DESCRIPTION:Valid values for LNA are V, D when ACT = V.

RULE ID:LSNP_SVC_DET_LNA_3
DESCRIPTION:Valid values for LNA are B, C, D, H, L, M, N, P, R, S, T, V, W, X, Y.

RULE ID:LSNP_SVC_DET_CKR_1
DESCRIPTION:CKR valid length is 1-41 alphanumeric characters.

RULE ID:LSNP_SVC_DET_ECCKT_2
DESCRIPTION:For REQTYP = B and ACT = V ECCKT must be populated with N.

RULE ID:LSNP_SVC_DET_ECCKT_3
DESCRIPTION:Number of occurrences of the ECCKT field must equal the NPQTY value.

RULE ID:LSNP_SVC_DET_ECCKT_4
DESCRIPTION:ECCKT is required when LNA = C, D, M, T, R.

RULE ID:LSNP_REMARKS_1
DESCRIPTION:The valid size for REMARKS is 1-500 alphanumeric characters.